This standard specifies the method for the determination of the content of migratable elements antimony, arsenic, barium, cadmium, chromium, lead, mercury and selenium in toy materials by inductively coupled plasma atomic emission spectrometry (ICP-AES). This standard applies to the determination of the migratable elements antimony, arsenic, barium, cadmium, chromium, lead, mercury and selenium in toy materials. The analysis wavelength and method detection limit of each element are shown in Table 1.