This Japanese Industrial Standard specifies the testing method and measurement
techniques of the electromagnetic compatibility (EMC) for the stationary and portable
small polymer electrolyte fuel cell power system (hereafter referred to as "fuel cell
system").
This Standard is applied to the fuel cell system applicable to the following items
a) Type of fuel cell Polymer electrolyte fuel cell
b) Output Rated transmission output, less than 10 kW
Output mode Grid-connected operation, grid-independent operation or indepen-
dent operation of DC output or AC output, 220 V or less
Raw material and fuel Gaseous fuel (city gas, liquefied petroleum gas, etc.),
liquid fuel (kerosene etc.) or hydrogen
Operating pressure Maximum allowable working pressure of the portion
through which fuel gas passes, less than 0.1 MPa
System configuration Stationary and "portable dedicated power generation sys-
tem or cogeneration system stored in a package (except a micro fuel cell)